Synergy Research
Home Research Peptides Contact
Research Peptides
Home › Research Peptides › Guides › Bacteriostatic Water
Research guide

Bacteriostatic Water research guide

A factual reference for laboratories working with Bacteriostatic Water: what the material is, how it is handled and stored, how to read its certificate of analysis, and how to order it in Canada. It is written for in-vitro research and makes no claims about effects in people or animals.

What is Bacteriostatic Water?

Bacteriostatic water is sterile water to which 0.9% (weight per volume) benzyl alcohol has been added as a preservative. The benzyl alcohol inhibits the growth of bacteria that might be introduced each time a needle passes through the stopper, which is why the product is supplied in multi-use vials rather than single-use ampoules. It is the most common diluent for reconstituting lyophilised peptides in a laboratory.

Benzyl alcohol is a small aromatic alcohol that is miscible with water at this concentration. It gives the solution a faint characteristic odour and some absorbance in the ultraviolet near 257 nm, which matters if a reconstituted peptide solution is going to be measured by UV spectrophotometry. The solution is otherwise clear, colourless and unbuffered.

Synergy Research supplies bacteriostatic water in 10mL and 30mL sealed glass vials. It is listed under Solvents in the catalogue, and its certificate of analysis covers sterility and benzyl alcohol content rather than peptide purity.

Specification summary

Format
Sterile aqueous solution, multi-use sealed glass vial
Sizes
10mL and 30mL vials
Molecular formula
H2O with 0.9% (w/v) benzyl alcohol
Preservative
Benzyl alcohol, 0.9%

Values are taken from the product page and the public PubChem record. Each lot is confirmed against them by the independent testing reported on the certificate of analysis.

Research context

In the laboratory, bacteriostatic water is used to reconstitute lyophilised peptides and proteins for which a preservative is acceptable, and to prepare stock solutions that will be sampled repeatedly over days. Analytical papers on peptide stability often compare bacteriostatic water with sterile water and buffered diluents, because benzyl alcohol can alter the solubility and aggregation behaviour of some peptides.

Benzyl alcohol is also toxic to many cultured cells at the concentrations present here, so bacteriostatic water is generally not used as the final diluent for cell-culture experiments; peptide stocks made in it are diluted far enough into medium that the preservative concentration becomes negligible, or sterile water and phosphate-buffered saline are used instead.

Synergy Research does not evaluate, summarise or endorse the findings of any study. The material is supplied so that laboratories can design and run their own in-vitro experiments.

Storage and handling for laboratory use

Bacteriostatic Water is supplied as a ready-made solution, so the storage rules differ from those for lyophilised peptides. Keep sealed vials upright, away from light and at the temperature stated on the label; do not freeze a solution vial, since freezing can crack the glass and change the concentration through evaporation on thawing.

Store sealed vials at room temperature away from light. Once the stopper has been pierced, laboratory convention is to date the vial and discard it after 28 days, since the preservative is designed to suppress, not eliminate, contamination.

Once the stopper has been pierced, write the date on the label. Every entry through the stopper is a chance to introduce contamination, so use a fresh sterile needle and syringe each time and never return unused solution to the vial. Record the lot number in your laboratory notebook; it is the link between the vial and its certificate.

Working with the solution in the laboratory

Because the material is already in solution, there is no reconstitution step. The working concentration for an assay is obtained by withdrawing a measured volume with a sterile syringe and diluting it into the buffer or medium the method requires. Wipe the stopper with 70% alcohol and let it dry before each withdrawal.

Withdraw the volume you need with a sterile syringe and add it slowly to the lyophilised vial, down the inside wall, as described in each compound guide. Do not use bacteriostatic water for peptides whose guide notes that benzyl alcohol affects their solubility, or for solutions that will be added directly to cells.

Dilutions should be labelled with compound, concentration, lot number and date and used within the period your own stability data supports. Working dilutions are generally not stored; they are prepared fresh from the stock vial for each experiment.

How to read the Certificate of Analysis

Every lot Synergy Research sells is tested by an independent Canadian laboratory, and the resulting certificate is published on the Certificates of Analysis page. A certificate has three parts worth checking before you use a vial.

  • Identity. Mass spectrometry measures the molecular mass of the material and compares it with the theoretical value. For bacteriostatic water the certificate reports sterility, benzyl alcohol content by gas chromatography or HPLC (expected 0.9% w/v), pH and absence of particulates, rather than the HPLC purity and mass spectrometry used for peptides.
  • Purity. Reversed-phase HPLC with UV detection separates the main compound from related impurities. The area of the main peak as a percentage of total peak area is reported as purity. Look for the chromatogram itself, not only the number.
  • Traceability. The lot number on the certificate should match the number printed on your vial, and the certificate should name the testing laboratory and the date of analysis.

If a certificate for your lot is not yet posted, email [email protected] with the lot number and it will be sent when the laboratory report is in.

Frequently asked questions

What is the difference between bacteriostatic water and sterile water?

Both are sterile. Bacteriostatic water also contains 0.9% benzyl alcohol as a preservative, which allows the vial to be used more than once. Sterile water has no preservative and is for single use.

Can bacteriostatic water be used for cell culture?

Generally not as a final diluent, because benzyl alcohol is toxic to many cell lines. Make a concentrated peptide stock in it and dilute into medium, or use sterile water or phosphate-buffered saline.

How long can an opened vial be used?

Laboratory convention is 28 days after the stopper is first pierced, with the vial kept at room temperature and away from light. Date the vial when you open it.

What sizes are available?

Bacteriostatic water is supplied in 10mL and 30mL sealed glass vials.

Does benzyl alcohol interfere with UV measurements?

It absorbs near 257 nm, which can affect peptide quantification at 214 to 220 nm. Use a matched blank of bacteriostatic water or measure at 280 nm where possible.

Buy Bacteriostatic Water in Canada

Synergy Research supplies Bacteriostatic Water as 10mL and 30mL vials. Orders ship across Canada by Canada Post Xpresspost with tracking, and payment is accepted by Interac e-Transfer or card. Every vial is matched to a published certificate of analysis.

View Bacteriostatic Water product page →

See also: how to choose a research peptide supplier in Canada and the certificate archive.

For Research Use Only. Not for human or animal consumption, and not for use in diagnostic or therapeutic procedures. Nothing on this page describes, recommends or implies any use of this material in people or animals. See our Research Use Policy.

Why order from us
🚚

Fast, tracked shipping

Cold-chain protected where required, dispatched with tracking on every order.

👤

Real people, not bots

Questions answered by our team the same business day.

🧪

Research use only

For Research Use Only. Not for use in diagnostic or therapeutic procedures. Not for human or animal consumption.